Specifications
For Level/Interface Service:
Accuracy: ± 0.25 inch [± 6.4 mm]
Repeatability: ± 0.125 inch [± 3.2 mm]
For Temperature Service:
Accuracy: ± 2° F [± 1° C]
Repeatability: ± 1° F [± 0.6° C]
Response Time: As low as 3 seconds
Enclosure: NEMA 4X/IP66 Rated. Standard: Polyester power coated aluminum, with single 1" NPT conduit port. Optional: Stainless steel. Optional: Dual-conduit port, aluminum with 1/2" NPT pr M20 metric conduit ports.
Compliances and Agency Approvals: FM, FMc, ATEX, IECIx, EAC/TR CU, Inmetro. CE mark. PED, CRN.
Meets EC directives for EMC and LVD. Complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
FM/CSA/FMc: |
XP, Class 1, Div. 1 Groups B,C,D
DIP, Class II/III, Div. 1, Groups E,F,G
T4, Ta = 60°C, T3A, Ta = 60° |
ATEX: |
II 2 G Ex d IIC T6...T2 (effective Nov. 2014) |
IECEx |
Ex d IIC T6 or T5
Tamb (housing) = -40° to +40°C, T6
Tamb (housing) = -40° to +60°C, T5
Tp (sensing element) = -40° to 177°C, T4/T2 |
Optional N.I.S.T. Flow Calibration Services
Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
Flow Element
Materials of Construction: All welded 316L stainless steel electro-polished to 20 Ra for all wetted surfaces.
Process Connection: Sanitary flange
Insertion Length:
- 1.37 inch [35 mm] for 0.75 inch Tee
- 1.25 inch [32 mm] for 1 inch Tee
- 1.93 inch [49 mm] for 1.5 to 2 inch Tee
- 2.75 inch [70 mm] for 3 to 4 inch Tee
- Customer specified lengths are available as an option.
Operating Temperature:
- Standard: -4° to +350° F [-20° to +177° C]
- Optional: -100° to +500° F [-73° to +260° C] or -100° to +850° F [-73° to +454° C]
Operating Pressure: To 2000 psig [138 bar(g)]
Control Circuit
Operating Temperature: -40° to +140° F [-40° to +60° C]
Input Power: Field selectable 115 ± 15 Vac or 230 ± 30 Vac, 50/60 Hz; 21 to 28 Vdc or 18 to 26 Vac; 7 watts maximum.
Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc. Hermetically sealed relays are available as an option.
Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.
Electrical Connection: 1 inch female NPT
Remote Configuration: Available as an option with customer specified interconnecting cable length.