Specifications
Instrument
- Measuring Principal: Thermal dispersion
- Fluid Type: Natural gas
- Range
In-line
1 ″: 1 SCFM to 50 SCFM [1,6 NCMH to 80 NCMH]
2 ″: 2 SCFM to 200 SCFM [3,2 NCMH to 320 NCMH]
Insertion
Ordering Block 3, Code 3: 1.25 SFPS to 125 SFPS [0,4 NMPS to 38 NMPS]
Ordering Block 3, Code 4: 4 SFPS to 400 SFPS [1,2 NMPS to 122 NMPS]
- Accuracy: ± 1.5 % rdg, ± 0.5 % FS
- Temperature Compensation: 30 °F to 180 °F [-1 °C to 82 °C]
- Pressure Service: 10 to 50 psi(a) [0,7 to 3,5 bar(a)]
- Process Connections
In-line: 1 ″ or 2 ″ pipe tee, FNPT threads
Insertion: 1/2 ″ MNPT compression fitting with either Teflon or metal ferrule
- Repeatability: ± 0.5 % of reading
- Response Time: 4 sec. (1 time constant)
- Temperature Coefficient For temperatures > ± 30 °F [± 16 °C]
Maximum ± 0.025 % of reading / °F up to 250 °F [± 0,05 % of reading / °C up to 121 °C]
Flow Element
- Materials of Construction (Wetted Parts)
In-line: 316 stainless steel pipe tee; 316L stainless steel flow element
with Hastelloy C-22 thermowells
Insertion: 316L stainless steel with Hastelloy-C22 thermowells
- Operating Temperature: -40 °F to 250 °F [-40 °C to 121 °C]
Teflon ferrule maximum temperature is 200 °F [93 °C]
In-line: 225 psi [15.5 bar]
Insertion: 500 psi [34 bar]
Teflon ferrule maximum pressure is 150 psig [10 bar(g)]
6 ″ [152 mm] with variable insertion depth, 1/2 ″ MNPT compression fitting with Teflon or metal ferrule
12 ″ [305 mm] with variable insertion depth, 1/2 ″ MNPT compression fitting with Teflon or metal ferrule
Electronics
10 segment LED array, sequential lighting related to flow rate and flashing when trip point exceeded
Analog: 4-20 mA *
Relay: SPDT, 1A @ 24 Vdc, 120 Vac (ATEX: DC only)
Serial: RS232C I/O
* 500 ohm maximum load; user scalable, general purpose, uncalibrated output proportional to flow rate for trend monitoring or assignable to temperature; fault indication per NAMUR NE43 guidelines, user-selectable for high (> 21.0 mA) or low (< 3.6 mA) default
Free FCI set-up and configuration software utility program and 3-wire-to-DB9 RS232 dongle are supplied for interface of the FS10i to user's PC. This interface is required to set the 4-20 mA output for the specific line size, flow range, and engineering units, as well as alarm trip point, hysteresis, and trip time delay.
- Trip Point Hysteresis Control: 0-100% of span
- Trip Point Time Delay: user settable for 0-65,000 seconds
- Input Power: 24 Vdc (21.5 Vdc to 30 Vdc); 2.5 watts maximum
- Operating Temperature: -40 °C to 160 °F [-40 °C to 71 °C]
Enclosure / Housing
- Material: stainless steel body; aluminum end-cap/top with polyester overlay and clear, silicone sheath impact guard
- Protection Ratings
Non-Ex installations: IP65, IP66, IP67
FM, FMc approved: NEMA 4X
ATEX, IECEx approved: IP64
FM , FMc Nonincendive, Class I Division 2 Groups A, B, C, D;
Class II, Division 2 Groups E, F, G; Class III,
T4@Ta=71°C, Type 4X
ATEX , IECEx Nonincendive for gas and dust, Zone 2/Zone 22
II 3 G Ex ec IIC T4 Gc, -40°C ≤ Ta ≤ +71°C
II 3 D Ex tc IIIC T81 °C Dc, -40°C ≤ Ta ≤ +71°C
IP64
Others: EAC/TR CU
Ingress Protection: IP65, IP66, IP67 in non-hazardous locations
CE Marking, CRN, complies with Canadian Electrical code requirements of ANSI / ISA 12.27.01-2011 as a single seal device
- IEC 61508 (SIL): SIL 2 Compliant with Hardware Fault Tolerance (HFT) of 0; Safe Failure Fraction (SFF) 90%
- Warranty: 1 Year
Certification/Approvals
- FM , FMc Nonincendive, Class I Division 2 Groups A, B, C, D;
Class II, Division 2 Groups E, F, G; Class III,
T4@Ta=71°C, Type 4X
- ATEX , IECEx Nonincendive for gas and dust, Zone 2
II 3 G Ex ec IIC T4 Gc, -40°C ≤ Ta ≤ +71°C
II 3 D Ex tc IIIC T81 °C Dc, -40°C ≤ Ta ≤ +71°C, IP64
- EAC/TR CU
- Ingress Protection IP65, IP66, IP67 in non-hazardous locations
- CE Marking, CRN, complies with Canadian Electrical code requirements of ANSI / ISA 12.27.01-2011 as a single seal device
- IEC 61508 (SIL) SIL 2 Compliant; Safe Failure Fraction (SFF) 90%