Specifications
For Level/Interface Service:
Accuracy: ± 0.25 inch [± 6.4 mm]
Repeatability: ± 0.125 inch [± 3.2 mm]
For Temperature Service:
Accuracy: ± 2° F [± 1° C]
Repeatability: ± 1° F [± 0.6° C]
Response Time: As low as 3 seconds
Enclosure: Aluminum enclosure is rated for hazardous location use (Class I and II, Division 1 and 2, Group B, C, D, E, F and G; and EEx d IIC) and resists the effect of weather and corrosion (NEMA and CSA Type 4X and equivalent to IP66).
Agency Approvals: Contact FCI.
Flow Element
Materials of Construction: 316 stainless steel tubing for all wetted surfaces. Hastelloy C is available as an option.
Process Connection: 2 inch diameter tubing with 4 inch 150 lb raised face flange
Insertion Length: Customer specified up to 25 feet [7620 mm]
Operating Temperature:
- Standard: -4° to +350° F [-20° to +177° C]
- Optional: -100° to +500° F [-73° to +260° C]
Operating Pressure: To 3500 psig [240 bar(g)]
Control Circuit
Operating Temperature: -40° to +140° F [-40° to +60° C]
Input Power: Field selectable 115 ± 15 Vac or 230 ± 30 Vac, 50/60 Hz; 21 to 28 Vdc or 18 to 26 Vac; 7 watts maximum.
Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or
24 Vdc. Hermetically sealed relays are available as an option.
Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.
Electrical Connection: 1 inch female NPT